Robinair troubleshooting manual. ROBINAIR 34788NI ORIGINAL INSTRUCTIONS MANUAL Pdf Download. 2019-01-24

Robinair troubleshooting manual Rating: 6,7/10 1065 reviews

Robinair SPX 34134Z Refrigerant Unit Recover Recycle Recharge Owners Manual

robinair troubleshooting manual

The number I called 1-800-822-5561. The operator must be familiar with air conditioning and refrigeration systems, refrigerants, and the dangers of pressurized components. You must verify that conditions and procedures do not jeopardize your personal safety. The machine enters a 5-minute vacuum and will automatically enter the next set-up process when complete. Heating, Ventilating and Air Conditioning User Manual Free Download. Do not overfill the internal storage vessel, because overfilling may cause explosion and personal injury or death. Do not attempt to adapt the machine for another refrigerant.

Next

ROBINAIR 34788NI ORIGINAL INSTRUCTIONS MANUAL Pdf Download.

robinair troubleshooting manual

Disconnect hoses with extreme caution. Wear protective equipment, including safety goggles. If calibration continues to fail, contact an authorized Robinair service center for assistance. Refer to Tank Fill in Maintenance section of this manual. Purge excess air from the tank manually. Contact the manufacturer for a replacement power cord. If problem continues, contact a Robinair authorized service center for more information.

Next

Robinair SPX ROB134APF Recovery Recycling Recharging Unit Owners Manual

robinair troubleshooting manual

Problems resulting from the use of non-approved oils will. Note: There is no need to calibrate the scale; it is calibrated at the factory. Lubricate wheel bearings and inspect brake components Monthly. Select to set the selected language. Exposure may cause personal injury, especially to the eyes, nose, throat, and lungs. All models of the machine already contain a printer connection harness that is ready for use.

Next

Troubleshooting guide

robinair troubleshooting manual

The call to the tech line took about 5 mins. Note: The vacuum process will halt if pressure rises above. The machine got stuck in Clr or Clearing while changing from R-12 to R-134a. Robinair, based out of Owatonna, Minnesota, sells products worldwide through wholesalers and automotive distributors. B, February 10, 2015 © Bosch Automotive Service Solutions Inc.

Next

Robinair User Manuals

robinair troubleshooting manual

. Exit current test and contact a Robinair authorized service center for more information. The user must verify that conditions and procedures do not jeopardize personal safety. Performed by an authorized Pressure Test Robinair service center. Note: Add at least 3. The right is reserved to make changes at any time without obligation to notify any person or organization of such revisions or changes.

Next

Robinair SPX 34134Z Refrigerant Unit Recover Recycle Recharge Owners Manual

robinair troubleshooting manual

Drain the oil bottle, and dispose of the oil according to applicable regulations. Do not recover or charge refrigerants into non-refillable containers; use only authorized refillable containers. If pressure exists or refrigerant enter the recovery mode to recover refrigerant through both the high-side red and low-side blue hoses. Exposure may cause personal injury, especially to the eyes, nose, throat, and lungs. If the Product the Licensee receives hereunder contains Third Party-Owned software the Licensee agree to comply with all terms and conditions imposed on you in respect of such Third Party-Owned software. All performance tests and claims are based on using this specific filter. The Robinair 34700Z is an automotive air-conditioning service machine.

Next

Troubleshooting guide

robinair troubleshooting manual

I called tech support and they walked me through a process that resets the machine. English is the default language. The viscosity of the oil being injected significantly affects the accuracy. The operator must be familiar with air conditioning and refrigeration systems, refrigerants, and the dangers of pressurized components. Contact a Robinair authorized service center for more information. Open the source tank valve. If the tank R-12 or R134a does not have at least 10 pounds of refrigerant in the tank before you change to another refrigerant, the machine will stay in the clearing process.

Next

How to Troubleshoot a Robinair 34700Z

robinair troubleshooting manual

The display shows how long the vacuum time without the oil fill port cap installed, pump has operated since the last oil change. Remove the bandings from the box. A tripped circuit breaker will cause the machine to lose all power. If the breaker trips, its button will pop out. Hope this will solve your problem, if so please vote for it for farther help! Robinair cannot know, evaluate, or advise as to all possible hazards. You may then install the software. Contact with refrigerant may cause personal injury.

Next

ROBINAIR 34788NI OPERATING MANUAL Pdf Download.

robinair troubleshooting manual

No title or other rights in the Licensed Product other than rights expressly granted herein shall pass to the Licensee. The right is reserved to make changes at any time without obligation to notify any person or organization of such revisions or changes. Remove the oil drain bottle from the machine by pulling the bottle straight down—do not use a twisting or rocking motion. You must make sure all conditions and procedures do not jeopardize your personal safety. Select Unit Activation from the Setup Menu.

Next

Robinair SPX 34134Z Refrigerant Unit Recover Recycle Recharge Owners Manual

robinair troubleshooting manual

Verify connections are secure and valves are in correct position. Use the unit in locations with mechanical ventilation that provides at least four air changes per hour. The user may select Refrigerant could spray out of the fittings, to print the summary, if a printer is installed. To install a printer: 1. Refer to Tank Fill in the Maintenance section of this manual. The machine is equipped with special connectors to recover, recycle, and recharge only R-134a refrigerant.

Next